ThermoRef pyrometer

The ThermoRef measures surface temperature without contact, from 500 to 3000 °C depending on the model. It measures the target's emissivity in real time: the temperature stays right when a metal oxidizes, melts or changes appearance, with no user adjustment.

Measurement principle

The ThermoRef measures both the radiation emitted by the target and the light it reflects, at two wavelengths. From these it derives the surface's emissivity and diffusion factor, and then its true temperature. The measurement takes four steps:

An active measurement: two lasers illuminate the target intermittently, the difference gives the reflectivity, and the ThermoRef derives the true temperature with no emissivity setting.
  1. 1

    Two radiances

    Two photodiodes measure the radiation emitted by the target, at 1.3 and 1.5 µm.

  2. 2

    Two reflectivities

    Two lasers at the same wavelengths light the target, and the ThermoRef measures the share reflected at each.

  3. 3

    Diffusion factor

    By combining the measurements, and assuming the surface reflects light the same way at two close wavelengths, the calculation determines the diffusion factor.

  4. 4

    True temperature

    Emissivity is corrected in real time and the ThermoRef displays the pyroreflectometric temperature, along with the single-color and two-color temperatures for comparison.

Independent of the viewing angle. The combined calculation is designed not to depend on the measurement angle, which makes installation easier.

Emissivity your other instruments can use. The ThermoRef displays the measured emissivity, which you can enter into an infrared camera or a single-color pyrometer.

An optical head connected by fiber. The measuring head is connected to the electronics by an optical fiber (2 m as standard): the measurement is not disturbed by electromagnetic fields, such as those of induction heating.

Tests on materials

Each material has its own difficulties: shiny surfaces, oxidation, melting. We measured the temperature of several materials to show what the ThermoRef brings.

Chart comparing temperatures measured on aluminum with the ThermoRef, a thermocouple and a bichromatic pyrometer.
ThermoRef measurement on aluminum Temperatures measured while heating an aluminum plate until it melts: ThermoRef, thermocouple and bichromatic temperature.

On an aluminum plate heated until it melts, the bichromatic temperature stays several tens of degrees too high, while the ThermoRef temperature is the closest to the thermocouple. At first, the gap with the thermocouple comes from its poor contact with the metal; around 580 °C, when the aluminum starts to melt, the thermocouple sinks into it, contact becomes perfect and both measurements meet.

A temperature that is hard to measure?

Tell us about your material, the temperature range and your installation: we will tell you whether the ThermoRef is right for you.

Discuss your application See the pyrometers Read the reflectometric pyrometry guide