Static pressure by interferometry
To measure static or quasi-static pressure, we use interferometry: a Fabry-Perot cavity, formed between the end of the fiber and a silicon diaphragm, changes length with pressure. This is the principle of the Delphinus sensor.
Measuring principle
The principle in three steps
- 01
A Fabry-Perot cavity
Light is reflected by the end of the fiber and by the silicon diaphragm. The two reflections interfere: the gap between them forms a Fabry-Perot cavity.
- 02
Pressure changes the cavity
Pressure deflects the diaphragm and shortens the cavity. In the reflected spectrum, the spacing between interference fringes changes with the cavity length; the conditioner derives the pressure from it.
- 03
Temperature is compensated
A Bragg grating (FBG) written in the sensor's fiber measures the temperature at the same point. The conditioner corrects its effect on the pressure measurement.
The Delphinus sensor
- Measurement
- Absolute (vacuum reference) or differential
- Range
- Up to 50 bar
- Temperature
- 125 °C as standard
- Compensation
- Built-in Bragg grating
Versions up to 800 °C are under development.