Non-contact temperature
Materials R&D: superalloys, ceramics and composites at high temperature
Measure without contact the true temperature of superalloys, ceramics and ceramic-matrix composites, even when their surface oxidizes or changes appearance during the test.
Backed by measurements See the results

The need
In high-temperature materials research, the sample temperature is the basic data of the test. On a nickel-based superalloy, a ceramic or a ceramic-matrix composite, the surface changes during heating, holding and cooling: oxidation, roughness, phase change.
A thermocouple is not always possible (small part, fragile surface, closed chamber): the measurement then has to be non-contact.
Why conventional sensors fall short
- A conventional pyrometer requires an emissivity setting, while emissivity changes during the test.
- A two-color pyrometer assumes emissivity is the same at both wavelengths, which is wrong for many materials.
- Adjusting emissivity to match a thermocouple makes the measurement operator-dependent.
- A bonded or welded thermocouple can come loose or alter the sample.
What ThermoRef brings
- Temperature calculated from measurements, with no emissivity setting by the user
- Emissivity measured in real time at both wavelengths (1.3 and 1.55 µm)
- Fallback temperatures (two-color, emissivity-corrected) when the direct calculation is not possible
- Access to raw signals to check or reprocess the measurements
Measurement results
We measured the temperature of several difficult materials to show what ThermoRef brings.
On a heated 316L stainless steel plate, the surface is shiny at first, then becomes covered with oxide layers that change during heating: emissivity changes constantly, the ideal use case for ThermoRef. We also measured a ceramic in a crucible heated above 900 °C and graphite in a furnace.
In our evaluations, the temperature obtained without any emissivity setting is most often within 5 to 10 °C of the thermocouple, depending on the phase of the cycle and the surface condition.
Phonoptics tests. Differences with the thermocouple from the ThermoRef white paper.
Implementation
- The optical head sits away from the sample, at the chosen working distance (from 20 cm to about 1.5 m), through a viewport if needed.
- ThermoRef is calibrated on a blackbody for luminance and on a white reference for reflectivity, in the measurement geometry. After that, the operator sets no emissivity.
- During the test, it displays the direct temperature, the emissivities and the fallback temperatures, and logs them to SD card.
- ThermoRef Standard covers 500 to 1500 °C, ThermoRef HT 750 to 3000 °C.
Products used
An application close to yours?
Tell us about your installation, the temperature range and what you need to detect: we will propose the right sensor, membrane and conditioner.
Other application cases
-
Backed by measurements
Foundry: aluminum and molten metals
Measure without contact the temperature of a liquid metal whose surface shines and oxidizes. View the case
-
Welding: weld bead temperature
Track the temperature of the weld bead and the surrounding area, without contact and with no emissivity setting. View the case
-
High-temperature fatigue, tensile and ageing tests
Track the temperature of a specimen during a long test, with no thermocouple coming loose and despite oxidation. View the case
-
Metal additive manufacturing: layer temperature
Track the temperature of layers and deposits in metal additive manufacturing, on surfaces that change constantly. View the case