Application cases

Non-contact temperature

Materials R&D: superalloys, ceramics and composites at high temperature

Measure without contact the true temperature of superalloys, ceramics and ceramic-matrix composites, even when their surface oxidizes or changes appearance during the test.

Backed by measurements See the results

Discuss your application

Materials R&D: superalloys, ceramics and composites at high temperature

The need

In high-temperature materials research, the sample temperature is the basic data of the test. On a nickel-based superalloy, a ceramic or a ceramic-matrix composite, the surface changes during heating, holding and cooling: oxidation, roughness, phase change.

A thermocouple is not always possible (small part, fragile surface, closed chamber): the measurement then has to be non-contact.

Why conventional sensors fall short

  • A conventional pyrometer requires an emissivity setting, while emissivity changes during the test.
  • A two-color pyrometer assumes emissivity is the same at both wavelengths, which is wrong for many materials.
  • Adjusting emissivity to match a thermocouple makes the measurement operator-dependent.
  • A bonded or welded thermocouple can come loose or alter the sample.

What ThermoRef brings

  • Temperature calculated from measurements, with no emissivity setting by the user
  • Emissivity measured in real time at both wavelengths (1.3 and 1.55 µm)
  • Fallback temperatures (two-color, emissivity-corrected) when the direct calculation is not possible
  • Access to raw signals to check or reprocess the measurements
How ThermoRef works

Measurement results

We measured the temperature of several difficult materials to show what ThermoRef brings.

On a heated 316L stainless steel plate, the surface is shiny at first, then becomes covered with oxide layers that change during heating: emissivity changes constantly, the ideal use case for ThermoRef. We also measured a ceramic in a crucible heated above 900 °C and graphite in a furnace.

In our evaluations, the temperature obtained without any emissivity setting is most often within 5 to 10 °C of the thermocouple, depending on the phase of the cycle and the surface condition.

Heated 316L stainless steel plate, with the ThermoRef beam aligned on the heated area: the initially shiny surface becomes covered with oxides during heating.
Heated 316L stainless steel plate, with the ThermoRef beam aligned on the heated area: the initially shiny surface becomes covered with oxides during heating.
Ceramic in a crucible heated above 900 °C.
Ceramic in a crucible heated above 900 °C.
Graphite in a furnace, measured through the furnace opening.
Graphite in a furnace, measured through the furnace opening.

Phonoptics tests. Differences with the thermocouple from the ThermoRef white paper.

Implementation

  1. The optical head sits away from the sample, at the chosen working distance (from 20 cm to about 1.5 m), through a viewport if needed.
  2. ThermoRef is calibrated on a blackbody for luminance and on a white reference for reflectivity, in the measurement geometry. After that, the operator sets no emissivity.
  3. During the test, it displays the direct temperature, the emissivities and the fallback temperatures, and logs them to SD card.
  4. ThermoRef Standard covers 500 to 1500 °C, ThermoRef HT 750 to 3000 °C.

Products used

An application close to yours?

Tell us about your installation, the temperature range and what you need to detect: we will propose the right sensor, membrane and conditioner.

Discuss your application