Application cases
Acoustics and dynamic pressure
Covert listening for defense and security
Listen to a place with a microphone that contains no electronics and emits nothing: the recorder stays safe, more than 10 km away at the end of a fiber.
An application to study with you: we size the sensor for your installation.

The need
Defense, intelligence and security agencies need to listen to a place without the device being detected or jammed, and without going back on site to power it or collect recordings.
The listening point must be as discreet as possible; the electronics must stay safe and far away.
Why conventional sensors fall short
- An electrical microphone, its cable and its power supply emit electromagnetic radiation that detection equipment can find.
- A radio transmitter can be jammed and located.
- Batteries mean going back on site.
- Electromagnetic interference degrades listening.
What fiber optics brings
- No electronics or electrical energy at the listening point: nothing to detect, nothing to jam
- All-plastic version (Evotis Plastic), with no metal parts
- A single, very thin fiber between microphone and recorder, over more than 10 km
- Phantom recorder: recording to SD card, Ethernet access, programmable recording schedules
Implementation
- The Evotis microphone is placed at the listening point. Only the fiber links it to the electronics.
- The very thin fiber can follow an existing path and run beyond 10 km.
- The Phantom unit, kept safe, records to SD card on the programmed schedule and is accessed over Ethernet.
- This equipment is intended for authorized agencies: contact us to discuss it.
Products used
An application close to yours?
Tell us about your installation, the temperature range and what you need to detect: we will propose the right sensor, membrane and conditioner.
Other application cases
-
Backed by measurements
Weld monitoring: porosity and wire-stuck detection
Detect porosity and wire sticking live in TIG welding, right next to the arc, free from electromagnetic interference. View the case
-
Backed by measurements
Ultrasonic cleaning bath testing
Measure inside the liquid the ultrasonic emission of a cleaning bath and its homogeneity, harmonics included. View the case
-
Backed by measurements
Electric arcs and predictive maintenance
Characterize the sound of an electric arc and detect equipment drift, with a sensor the arc cannot disturb. View the case
-
Combustion: instabilities, knock and exhaust
Measure dynamic pressure right next to the combustion, without cooling, up to 850 °C. View the case