Application cases

Acoustics and dynamic pressure

Furnaces: hearing silicon wafers split

Hear, during the heat treatment, the moment a silicon wafer splits or cracks, with an acoustic sensor that withstands the furnace temperature.

An application to study with you: we size the sensor for your installation.

Discuss your application

Furnaces: hearing silicon wafers split

The need

In some microelectronics processes, a silicon wafer splits in two during an anneal: the split happens at temperature, inside the furnace. Other heat treatments can crack or break wafers.

Each split or crack releases mechanical energy, audible as a crack. Detecting it live gives the exact time of the event, helps optimize the anneal duration and flags a broken wafer without opening the furnace.

Why conventional sensors fall short

  • Electrical microphones cannot withstand the furnace temperature.
  • Heating elements and their power supplies create electrical interference.
  • A sensor placed outside the furnace, behind the wall, no longer hears weak events.

What fiber optics brings

  • Sensors that withstand the temperature: Evotis HT up to 350 °C, Alpheus THT up to 600 °C
  • No electronics in the furnace, no interference picked up
  • Miniature head that fits close to the wafers
  • Wide bandwidth to tell a crack from furnace noise
Why fiber optics?

Implementation

  1. The sensor sits inside the furnace, as close as possible to the boat holding the wafers. The fiber exits through a wall feedthrough.
  2. Under vacuum, sound does not travel through air: the sensor is then mounted in contact with the holder to pick up the wave traveling through it.
  3. The version follows the anneal temperature: Evotis HT up to 350 °C, Alpheus THT up to 600 °C.
  4. The conditioner, outside the furnace, sends the signal to your acquisition system, which detects and time-stamps each crack.

Products used

An application close to yours?

Tell us about your installation, the temperature range and what you need to detect: we will propose the right sensor, membrane and conditioner.

Discuss your application