Acoustics and dynamic pressure
Railways: listening to level crossings near overhead lines
Check and record level-crossing audible signals with a microphone installed next to electrified tracks, with no electrical link to the trackside cabinet.
An application to study with you: we size the sensor for your installation.

The need
On an electrified line, level-crossing bells must sound every time the barriers close. Listening to and recording them makes it possible to check they work remotely and to keep a record in case of an incident.
The microphone is then close to the overhead line and the rails, in a harsh electrical environment, while recording takes place in a cabinet that may be far away.
Why conventional sensors fall short
- The overhead line and the return current in the rails induce interference in electrical cables, which drowns the audio signal.
- An overvoltage (fault, lightning) can travel along a copper cable to the cabinet and damage it.
- Long cables between the microphone and the cabinet degrade the signal.
- The equipment must withstand outdoor conditions all year round.
What fiber optics brings
- Full galvanic isolation: the fiber does not conduct electricity
- No interference picked up, even at the foot of the overhead line
- Long fiber runs to the cabinet with no loss of quality
- IP65 Evotis microphone, 20 Hz to 15 kHz bandwidth
Implementation
- The Evotis microphone is mounted near the level crossing, facing the bell.
- The fiber reaches the cabinet along the existing cable routes.
- In the cabinet, a MiniMyotis conditioner delivers the signal to your system, or a Phantom unit records it to SD card and makes it available over Ethernet.
- A multichannel conditioner monitors several listening points.
Products used
An application close to yours?
Tell us about your installation, the temperature range and what you need to detect: we will propose the right sensor, membrane and conditioner.
Other application cases
-
Backed by measurements
Weld monitoring: porosity and wire-stuck detection
Detect porosity and wire sticking live in TIG welding, right next to the arc, free from electromagnetic interference. View the case
-
Backed by measurements
Ultrasonic cleaning bath testing
Measure inside the liquid the ultrasonic emission of a cleaning bath and its homogeneity, harmonics included. View the case
-
Backed by measurements
Electric arcs and predictive maintenance
Characterize the sound of an electric arc and detect equipment drift, with a sensor the arc cannot disturb. View the case
-
Combustion: instabilities, knock and exhaust
Measure dynamic pressure right next to the combustion, without cooling, up to 850 °C. View the case